Approvals & Standards

 

  • Complies to Automotive IATF 16949:2016 Quality System
  • IEC 60 269-4
  • ISO 8820-8
  • JAS0 D622

 

Key features & benefits

EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications.
EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry.
The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection.
The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.

More specifications

Applications

 

  • EV/HEV
  • Battery pack protection
  • Battery Disconnect Unit (BDU)
  • Battery Management Systm (BMS)
  • Battery Junction Box for auxiliaries
  • On-Board Charging

 

Product Specifications

Item Number

MEV50A300-30G  

Catalogue No.

MEV50A300-30G  

Description

EVpack Fuse 500VDC UL 500VDC IEC 300A Size 30G Max. Rated Breaking Capacity DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Bolted  

EAN/UPC Code

6972238870264  

Rated voltage DC UL

500   V

Rated voltage DC IEC

500   V

Ampere Rating

300   A

ROHS Compliant

Yes  

AC or DC

DC  

Speed/Characteristic

aR  

Fuse Size

30G  

Mounting

Bolted  

Melting I2t

18440   A²s

Max. Rated Breaking Capacity DC

30 kA @ 500 V, L/R ≤ 2.5ms  

Max. Time to clear MBC

0.5   s

DC Min. Breaking Capacity (MBC)

1500 A @ 500 VDC, ≤ 2.5 ms  

DC Total clearing I2t

146000 A²s  

Power Dissipation at Intermediate Current Value

7.5 W @ 0.5 In  

Connection/Terminal Material

Tin-Plated Copper  

Connection/Terminal Type

Bolted  

Body/Insulating Material

GMG  

Product Weight

0.22   lb

Product Diameter

1.18   in

Product Length

3.62   in

Sell Pack Quantity

12   EA

Sell Pack Weight

2.646   lb

Sell Pack Width

10.87   in

Sell Pack Length

6.46   in

Sell Pack Height

3.74   in