Skip to main content

All locations

Please select your country & language

China | 中国
Germany | Deutschland

Your country is not in the list?

Go to our international website:

Mersen EP International website
Country / Language:  USA / English
Contact us

Approvals & Standards

  • IEC/EN 60 947-3
  • For NH-fuse links size 2 in accordance with IEC/EN 60 269-2, VDE 0636-2

Key features & benefits

The production programme of MULTIBLOC® series 2.ST8 comprises NH fuse switch disconnectors for 400A.
They are designed for bottom fitting/panel installation and are available in triple pole and quadruple pole units.
For installation of MULTIBLOC® NH fuse switch disconnectors in distribution units with central cover, respective covers are used to obtain a uniform profile in height and length.
MULTIBLOC® size 2 are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2, 400A.
MULTIBLOC® offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance.

More specifications

Applications

  • Panel boards for industrial use
  • Feeder pillars for industrial use
  • Meter distribution units
  • Measuring transformer cabinets
  • Transmitting stations for telecommunications

Product Specifications

Item Number

H1023070  

Catalogue No.

1.002.712  

Description

NH fuse-switch disconnector MULTIBLOC® Size 2 400A 3-Pole switching Bottom Fitting/panel Connection Screw M10 elec mon.  

EAN/UPC Code

9008567005897  

Frequency

50 ... 60   Hz

Rated voltage AC IEC

690   V

Ampere Rating

400   A

Utilization Category

AC 23 B @ Ue = AC 400 V; Ie = 400 A  

Utilization Category

AC 22 B @ Ue = AC 500 V; Ie = 400 A  

Utilization Category

AC 21 B @ Ue = AC 690 V; Ie = 315 A  

Utilization Category

DC 21 B @ Ue = DC 440 V; Ie = 400 A  

Switchability

3-,4-pole switching  

ROHS Compliant

Yes  

Short Circuit Current Rating (SCCR)

80kA@Ue = AC 400 V; Ie = 400 A / 80kA@Ue = AC 500 V; Ie = 400 A / 80kA (3-pole)@Ue = AC 690 V; Ie = 315 A / 50kA (4-pole)@Ue = AC 690 V; Ie = 315 A  

Fuse Size

2  

Design Details

with electronic fuse monitoring ESÜ installed (rated voltage=525VAC)  

Number of Poles

3-Pole  

Degree of Pollution

3  

Rated Duty

uninterrupted duty  

Rated Impulse Withstand Voltage

12   kV

Rated Insulation Voltage

1000   V

Rated SC Withstand

13 kA / 1 s  

Conventional Free Air thermal Current With Fuse-Links Ith

400   A

Conventional Free Air thermal Current - Solid Links

630   A

Max Power dissipation of Fuse Links Pn

34   W

Max Power dissipation of Solid Links Pn

9   W

Power Dissipation by Ith without Fuse-Links

27   W

Power Dissipation by Ith without Solid Links

67   W

Rated short circuit making capacity with solid links Icm

10.6   kA

Installation Mounting

Bottom Fitting/panel  

Comments

Cable termination components : 6 M10 terminal screws  

Product Weight

7.937   lb

Product Width

8.05   in

Product Length

5.87   in

Product Height

10.2   in

Sell Pack Quantity

1   EACH

Sell Pack Weight

7.937   lb

Sell Pack Width

8.19   in

Sell Pack Length

10.31   in

Sell Pack Height

5.24   in