Catalog

Low Voltage UL/CSA Fuses

Class RK1

A6D-R - Class RK1 - Time-Delay

Amp-Trap 2000 SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace obsolete 600V Class H, K or RK5 fuses already installed in the field.

 

FEATURES

  • Solid-state SmartSpot indicator
  • Time-delay for motor starting and transformer inrush currents without nuisance opening
  • 300kA interrupting rating, self-certified (UL witnessed test
  • Extremely current-limiting for low peak let-thru current
  • Easy 2-to-1 selectivity for prevention of nuisance shut downs and "black outs"
  • Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
  • High-visibility orange label gives instant recognition
  • Reduced inventory by taking the place of Class RK5, K, and H fuses
  • Metal embossed date and catalog number for easier traceability and lasting identification
  • Fiberglass body provides dimensional stability in harsh industrial settings
  • High-grade silica filler ensures fast arc quenching
 

PRODUCT DETAILS

  • Volts (VAC) 600 VAC
  • Volts (VDC) 600 VDC
  • Ampere Range (A) 1/10-600 A
  • I.R. AC (kA) 200 kA
  • I.R DC (kA) 100 kA
  • IR Other (kA) 300kA 600VAC
    Self Certified (UL Witnessed)
  • Class Class RK1
  • Speed / Characteristic Time-Delay
  • Mounting Clip
  • Connection Terminal Type Ferrule
    Blade
  • Body Style Cylindrical
    Rejection
  • Body Material Polyester
  • Materials Contact Tin-plated Copper
  • Standards UL Listed to Standard 248-12, File E2137
    DC Listed to UL Standard 248
    CSA Certified to Standard C22.2, No. 248.12
  • Application Motors
    Safety Switches
    Transformers
    Disconnects
    Control Panels
    All General-purpose Circuits
  • ROHS Compliant Consult Technical Services
  • Lead Free Consult Technical Services
  • CE conformity Consult Technical Services
  • UL File Card E2137 JDDZ.E2137
  • CSA File Card Class: 1422-02 File: 012636_0_000
 

Catalog-Reference

  • A6D1-1/4R - D219883
  • A6D1-1/8R - V222566
  • A6D1-4/10R - L223087
  • A6D1-6/10R - R200874
  • A6D1-8/10R - D201414
  • A6D1/10R - R201932
  • A6D1/2R - P211153
  • A6D100R - N211152
  • A6D10R - G211675
  • A6D110R - F211674
  • A6D125R - L212185
  • A6D12R - M212186
  • A6D15/100R - D212707
  • A6D150R - C212706
  • A6D15R - N213222
  • A6D17-1/2R - E213720
  • A6D175R - M213221
  • A6D1R - M214233
  • A6D2-1/2R - Q214742
  • A6D2-1/4R - T215251
  • A6D2-8/10R - X215760
  • A6D2/10R - C216271
  • A6D200R - D213719
  • A6D20R - C216777
  • A6D225R - L214232
  • A6D250R - P214741
  • A6D25R - Q217295
  • A6D2R - V217805
  • A6D3-1/2R - F218321
  • A6D3-2/10R - T218839
  • A6D3/10R - G219357
  • A6D300R - S215250
  • A6D30R - E219884
  • A6D350R - W215759
  • A6D35R - W222567
  • A6D3R - M223088
  • A6D4-1/2R - S200875
  • A6D4/10R - E201415
  • A6D400R - B216270
  • A6D40R - S201933
  • A6D450R - B216776
  • A6D45R - Q211154
  • A6D4R - H211676
  • A6D5-6/10R - N212187
  • A6D500R - P217294
  • A6D50R - E212708
  • A6D5R - P213223
  • A6D6-1/4R - F213721
  • A6D6/10R - N214234
  • A6D600R - T217804
  • A6D60R - R214743
  • A6D6R - V215252
  • A6D7/10R
  • A6D70R - E218320
  • A6D7R - Y215761
  • A6D80R - S218838
  • A6D8R - R217296
  • A6D90R - F219356
  • A6D9R - W217806
 

CAD & OUTLINE DRAWINGS

  • CAD Drawings

    • Drawing A6D(1-60)R :   PDF (42 KB)
    • Drawing A6D(110-200)R :   PDF (30 KB)
    • Drawing A6D(225-400)R :   PDF (31 KB)
    • Drawing A6D(450-600)R :   PDF (31 KB)
 

RESOURCES

Back

Find what you need fast...


Quick Links


Where to buy

ZIPCODE:

© 2017 Mersen S.A. All rights reserved.