Catalog

5 Result(s)

  • Changeover switches 7.2kV to 40.5kV
  • Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

    For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances and robustness for heavy duty requirements with very limited maintenance. Mersen offers one of the largest product ranges on the market and is the global leader. Mersen has a switch solution that will meet your unique needs. Our standard HUVS Change-over High Power Switches are rigorously engineered to meet your technical specifications. Operation : They can be operated manually, with a pneumatic piston or with an adapted motor (see list) up to 50.000 cycles thanks to fixed cast copper connections. Phase to Phase distance, Signaling, Terminal Box or Locking system can be studied and customized. Small making or braking capacity (on request) Maximum frequency up to 175Hz Indoor in a currentless state Ambient air should not exceed +40°C (otherwise please consult) Altitude should not exceed 1000 m Relative humidity should not exceed 95% List 2 following IEC 62271-1 Read more

  • Change-over Disconnectors HUVS Range 7.2kV (630 to 6300Amp)

    For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances and robustness for heavy duty requirements with very limited maintenance. Mersen offers one of the largest product ranges on the market and is the global leader. Mersen has a switch solution that will meet your unique needs. Our standard HUVS Change-over High Switches are rigorously engineered to meet your technical specifications. Operation : They can be operated manually, with a pneumatic piston or with an adapted motor (see list) up to 50.000 cycles thanks to fixed cast copper connections. Phase to Phase distance, Signaling, Terminal Box or Locking system can be studied and customized. Small making or breaking capacity (on request) Maximum frequency up to 175Hz Indoor in a currentless state Ambient air should not exceed +40°C (otherwise please consult) Altitude should not exceed 1000 m Relative humidity should not exceed 95% List 1 following IEC 62271-1 Read more

  • Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

    For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances and robustness for heavy duty requirements with very limited maintenance. Mersen offers one of the largest product ranges on the market and is the global leader. Mersen has a switch solution that will meet your unique needs. Our standard HUVS Change-over High Switches are rigorously engineered to meet your technical specifications. Operation : They can be operated manually, with a pneumatic piston or with an adapted motor (see list) up to 50.000 cycles thanks to fixed cast copper connections. Phase to Phase distance, Signaling, Terminal Box or Locking system can be studied and customized. Small making or braking capacity (on request) Maximum frequency up to 175Hz Indoor in a currentless state Ambient air should not exceed +40°C (otherwise please consult) Altitude should not exceed 1000 m Relative humidity should not exceed 95% List 2 following IEC 62271-1 Read more

  • Change-over Disconnectors HUVS Range 17.5kV (630 to 6300Amp)

    For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances and robustness for heavy duty requirements with very limited maintenance. Mersen offers one of the largest product ranges on the market and is the global leader. Mersen has a switch solution that will meet your unique needs. Our standard HUVS Change-over High Switches are rigorously engineered to meet your technical specifications. Operation : They can be operated manually, with a pneumatic piston or with an adapted motor (see list) up to 50.000 cycles thanks to fixed cast copper connections. Phase to Phase distance, Signaling, Terminal Box or Locking system can be studied and customized. Small making or braking capacity (on request) Maximum frequency up to 175Hz Indoor in a currentless state Ambient air should not exceed +40°C (otherwise please consult) Altitude should not exceed 1000 m Relative humidity should not exceed 95% List 2 following IEC 62271-1 Read more

  • Change-over Disconnectors HUVS Range 24kV (630 to 6300Amp)

    For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances and robustness for heavy duty requirements with very limited maintenance. Mersen offers one of the largest product ranges on the market and is the global leader. Mersen has a switch solution that will meet your unique needs. Our standard HUVS Change-over High Switches are rigorously engineered to meet your technical specifications. Operation : They can be operated manually, with a pneumatic piston or with an adapted motor (see list) up to 50.000 cycles thanks to fixed cast copper connections. Phase to Phase distance, Signaling, Terminal Box or Locking system can be studied and customized. Small making or braking capacity (on request) Maximum frequency up to 175Hz Indoor in a currentless state Ambient air should not exceed +40°C (otherwise please consult) Altitude should not exceed 1000 m Relative humidity should not exceed 95% List 2 following IEC 62271-1 Read more

Find what you need fast...


Quick Links


Where to buy

ZIPCODE:

© 2017 Mersen S.A. All rights reserved.