Catalog

Low Voltage UL/CSA Fuses

Class RK5

TR-R - Class RK5 - Time-Delay

Tri-Onic TR-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TR-R safely handle harmless starting currents and inrush currents associated with today’s motors and transformers.

 

FEATURES

  • Optional solid-state SmartSpot indicator
  • Time-delay for motor start-ups and transformer inrush currents without nuisance opening
  • Current-limiting for low peak let-thru current
  • Rejection-style design prevents replacement errors (when used with recommended fuse block)
 

PRODUCT DETAILS

  • Voltage Range (VDC) 160 - 250 VDC
  • Voltage Range (VAC) 250 VAC
  • Ampere Range (A) 1/10-600 A
  • I.R. AC (kA) 200 kA
  • I.R DC (kA) 20 kA
  • Class Class RK5
  • Speed / Characteristic Time-Delay
  • Mounting Clip
  • Connection Terminal Type Ferrule
    Blade
  • Body Style Cylindrical
    Rejection
  • Body Material Polyester
  • Materials Contact Copper
    Tin-plated Copper
  • Standards UL Listed to Standard 248-12, File E2137
    CSA Certified to Standard C22.2, No. 248.12
  • Application Motor Circuits
    Mains
    Feeders
    Branch Circuits
    Transformers
    Service Entrance Equipment
    General-Purpose Equipment
  • ROHS Compliant Yes
  • Lead Free Yes
  • CE conformity Yes
  • UL File Card E2137 JDDZ.E2137
  • CSA File Card Class: 1422-02 File: 012636_0_000
 

Catalog-Reference

  • TR1-1/4R - E217768
  • TR1-1/8R - Q218284
  • TR1-4/10R - E218803
  • TR1-6/10R - R219320
  • TR1-8/10R - S219850
  • TR1/10R - F222530
  • TR1/2R - Y223052
  • TR100R - K216738
  • TR100RID - K216738
  • TR10R - D200839
  • TR10RID - D200839
  • TR110R - B218800
  • TR110RID - B218800
  • TR125R - N219317
  • TR125RID - N219317
  • TR12R - S201381
  • TR12RID - S201381
  • TR15/100R - E201898
  • TR150R - P219847
  • TR150RID - P219847
  • TR15R - D211120
  • TR15RID - D211120
  • TR17-1/2R - S211639
  • TR17-1/2RID - S211639
  • TR175R - D222528
  • TR175RID - D222528
  • TR1R - Z212151
  • TR2-1/2R - Q212672
  • TR2-1/4R - A213187
  • TR2-8/10R - S213686
  • TR2/10R - Z214198
  • TR200R - V223049
  • TR200RID - V223049
  • TR20R - D214708
  • TR20RID - D214708
  • TR225R - A200836
  • TR225RID - A200836
  • TR250R - P201378
  • TR250RID - P201378
  • TR25R - G215217
  • TR25RID - G215217
  • TR2R - J215725
  • TR3-1/2R - Q216237
  • TR3-2/10R - N216741
  • TR3/10R - C217260
  • TR300R - B201895
  • TR300RID - B201895
  • TR30R - F217769
  • TR30RID - F217769
  • TR350R - A211117
  • TR350RID - A211117
  • TR35R - F218804
  • TR35RID - F218804
  • TR3R - T219851
  • TR4-1/2R - G222531
  • TR4/10R - Z223053
  • TR400R - P211636
  • TR400RID - P211636
  • TR40R - E200840
  • TR40RID - E200840
  • TR450R - N218282
  • TR450RID - N218282
  • TR45R - F201899
  • TR45RID - F201899
  • TR4R - A212152
  • TR5-6/10R - R212673
  • TR500R - C218801
  • TR500RID - C218801
  • TR50R - B213188
  • TR50RID - B213188
  • TR5R - E214709
  • TR6-1/4R - K215726
  • TR6/10R - R216238
  • TR600R - P219318
  • TR600RID - P219318
  • TR60R - P216742
  • TR60RID - P216742
  • TR6R - S218286
  • TR70R - Q219848
  • TR70RID - Q219848
  • TR75R - E222529
  • TR7R - G218805
  • TR8/10R - T219322
  • TR80R - W223050
  • TR80RID - W223050
  • TR8R - V219852
  • TR8RID - V219852
  • TR90R - B200837
  • TR90RID - B200837
  • TR9R - H222532
  • TR9RID - H222532
 

CAD & OUTLINE DRAWINGS

  • CAD Drawings

    • Drawing TR(61-100)R :   DXF (1.2 MB)
    • Drawing TR(101-200)R :   DXF (1.2 MB)
    • Drawing TR(201-400)R :   DXF (1.2 MB)
    • Drawing TR(1-30)R(ID) :   PDF (44 KB)
    • Drawing TR(35-60)R(ID) :   PDF (44 KB)
    • Drawing TR(70-100)R(ID) :   PDF (45 KB)
    • Drawing TR(110-200)R(ID) :   PDF (45 KB)
    • Drawing TR(225-400)R(ID) :   PDF (46 KB)
    • Drawing TR(450-600)R(ID) :   PDF (46 KB)
 

RESOURCES

Back

Find what you need fast...


Quick Links


Where to buy

ZIPCODE:

© 2017 Mersen S.A. All rights reserved.